igreatway
GW-LF series 6.6KW on-board charger is designed according to national standards and is a product that provides energy replenishment for vehicle power batteries. It meets the new national standards CC/CP, electronic lock, and temperature detection interface. The charger adopts CAN bus control to achieve information interaction with the vehicle BMS/VCU and feedback of working status. This product not only has the advantages of high efficiency, small size, high stability, and long life, but also has the characteristics of high protection level, high reliability, and complete protection functions. It is an ideal power supply for charging electric vehicles. The product has a built-in thermal sensing device with overheating protection function and can automatically recover. The fully sealed process and the protection level of up to IP67 can ensure that it can work in any complex environment without causing failures.
Input electrical characteristics | ||||||||
Rated input voltage | 220V AC | |||||||
Input voltage range | 90-265V AC | |||||||
Frequency | 45-65Hz | |||||||
Maximum input current | 32A | |||||||
Power factor | ≥0.99 above half load | |||||||
Standby power consumption | ≤5W | |||||||
Output electrical characteristics | ||||||||
Model No. | GW-LF-48-80 | GW-LF-80-80 | GW-LF-108-60 | GW-LF-144-44 | GW-LF-360-18 | GW-LF-540-12 | GW-LF-720-9 | |
Rated output voltage | 48v | 80v | 96V/108V | 144V | 360v | 540v | 720v | |
Output voltage range | 30V-80V | 50V-105V | 65V-140V | 90V-195V | 220V-450V | 350V-650V | 550V-850V | |
Output current range | 0-80A | 0-80A | 0-60A | 0-44A | 0-18A | 0-12A | 0-9A | |
Rated output power | 6.6KW(220VAC) 3.3KW(110VAC) | |||||||
Output mode | CC /CV | |||||||
Output constant voltage accuracy | 1% | |||||||
Output constant current accuracy | ±0.5A(Io≤10A)&≤±5%(Io>10A) | |||||||
Output response time | ≤200mS | |||||||
Voltage ripple coefficient | 1% | |||||||
Overall efficiency | ≥92% | ≥94% | ||||||
Protection function | ||||||||
Input overvoltage protection value | AC 270±5V | |||||||
Input undervoltage protection value | AC 85±5V | |||||||
Output overvoltage protection value | When the maximum output voltage exceeds +2%, the output stops. | |||||||
Output undervoltage protection value | When the minimum output voltage is lower than -5%, the output stops. | |||||||
Output overcurrent protection value | When the output current is greater than the maximum current, the output stops. | |||||||
Output reverse connection and short circuit protection | When the output is short-circuited or reversely connected, the protection shuts down, and the fault can be automatically restored after troubleshooting. | |||||||
CAN communication protection | when the CAN communication fails, the output stops automatically. | |||||||
Over temperature protection | When the heat sink temperature is higher than 75℃, the output power is reduced. When the temperature is higher than 90℃, the circuit is disconnected, and the output is restored when the temperature returns to below 85℃. | |||||||