1.5KW dc-dc converter with CANbus communication

Natural heat dissipation design, IP65 protection design; dual MCU control, all solid capacitors, planar transformer design; core components using automotive-grade standards.

Product main features:
Strengthen the production process design, strict selection of devices, to ensure product reliability and the mechanical strength .

Small volume, light weight, save space for the user greatly

System environment to a wide temperature range -40 ℃ ~ + 65 ℃, intelligent temperature derating; overtemperature protection
 Soft switching control technology, the system for maximum efficiency ≥ 95%.

Program online upgrade function, Convenient customer online debugging program and real-time updates, online self-diagnostic function, easy system maintenance.

Input characteristics

NO.

Item

Technical requirements

unit

Remarks

1.1

Rated input voltage

140~180

Vdc

Input voltage range

120—250

1.2

Maximum input current

9

A

Continuous Current

1.3

Static state battery drain current

≤10

mA

Battery drain current shutdown state

1.4

Input control voltage

9~33

Vdc

2, Output characteristics

2.1

Rated output voltage

13.8

Vdc

Rated input and output half load

2.2

Output voltage setting

13.8±0.2

Vdc

2.3

Output Current Range

0-110

A

When the input voltage drops below 480V, the output current linear derating(110A/480V—60A/400V).

2.4

Maximum output current

125

A

2.5

Output Power

1500/1600max

W

2.6

Overall efficiency

≥95

%

Rated input half load

2.7

Temperature Coefficient

≤±0.02

%/℃

2.8

Output ripple and noise

≤200

mVp-p

Oscilloscope bandwidth would be 20MHz, the probe capacitance in parallel 10u + 104

2.9

Starting time

≤2

S

27.5Vdc

Power input voltage to the output voltage established to 27.5Vdc

2.10

Voltage regulation accuracy

≤±1

%

2.11

Static loss current

≤10

mA

2.12

control method

Hardwired / software control

Hardware high enable

3, Protective properties

3.1

Input overvoltage protection

250-255

Vdc

3.2

Input Overvoltage recovery

240-250

Vdc

3.3

Input under voltage protection

100-120

Vdc

3.4

Input voltage recovery

110-125

Vdc

3.5

Output overvoltage protection

15-16

Vdc

Shutdown hiccups

3.6

Output under voltage protection

≤6

Vdc

Shutdown protection, self-recovery

3.7

Overcurrent protection

yes

/

3.8

Over-temperature protection

90℃

Environment temperature; automatic recovery

3.9

Output short circuit protection

yes

/

Shutdown protection, when the fault is removed can be automatically restored

3.10

Output reverse polarity protection

yes

/

Under static conditions when the 24v battery reversed, module protection, self-recovery when the fault is removed

3.11

Fan failure protection

yes

/

When a fan fault module automatically derating until the module overtemperature protection disables the output; als